Xiamen Andaxing Electric Group Co.,Ltd
products

Short Circuit and Earth Fault Detector

EKL4B Short Circuit and Earth Fault Detector indicates high voltage power line short circuit fault by detecting the 3 single-phase line-currents and short circuit currents, and the grounding fault by detecting the zero sequence currents. With visual or audible indicators, it helps line patrol staff to fast find out the location where there is a short circuit or grounding fault on the 3kV-40.5kV power distribution networks, switchgears or cable branching units etc.

  • item no.:

    EKL4B
inquiry now
details

Short Circuit and Earth Fault Detector EKL4B

 

Short circuit fault alarm indication

 

Short-circuit fault sensors installed on 3 single phase cables, monitoring the current changes of the power supply lines, when the current change value reach or exceed Threshold currents for short circuit alarm (this value can be set as per user requirement),the short circuit fault sensors output alarm signal, through optical fiber the signal will be sent to the indicator host, the corresponding fault indicator light will flash to alarm the short circuit fault.


Earth fault alarm indication

 

Earth fault sensor installed on the bifurcation unshielded part of three-phase cable, detecting the zero sequence current value of the three-phase cable, when its value reach or exceed Threshold currents for grounding fault alarm (this value can be set as per user requirement), the earth fault sensor outputs alarm signal through optical fiber, which will be sent to the indicator host, and the earth fault indicator light will flash to alarm the earth fault.


Features of Short Circuit and Earth Fault Detector EKL4B

 

* Short-circuit and earth fault detection with 3 single-phase current sensors, and one grounding current sensor

* Short-circuit indication (3 single phase L1,L2,L3) by three super bright LEDs respectively

* Earth fault indication by one super bright LED display

* Remote indication via 2 relay contacts

* Auxiliary power supply: 24V-230V DC/AC or built-in Li-ion battery with low-power-status indication

* Reset/Test Button

* Remote reset

* Auto-reset: 7s/8h/12h/24h reset time for options

Technical Parameter of Short Circuit and Earth Fault Detector EKL4B


Model number

EKL4B

Voltage level

3kV-40.5kV

Ambient

Temperature

 -25°C to +70°C

Humidity

95%

Threshold currents for short circuit alarm

150A-2000A

Threshold currents for grounding fault alarm

10A-100A

Alarm current accuracy

±10%

Alarm response time

Short circuit fault

40ms

Grounding fault

40ms

Working current

Stand by

≤10uA

Indication alarm

≤0.5mA

Auto reset time

7s/8h/12h/24h

Auxiliary power supply

Built-in battery

Li-ion 3.6v2.25Ah

External

24V-230V DC/AC

Capacity of relay contact 

2A 30VDC/1A 125VAC

Applicable conductor diameter

Short circuit sensor

type A

Φ20mm~Φ40mm

type B

Φ30mm~Φ50mm

type C

Φ50mm~Φ70mm

Grounding sensor

type A

Φ60mm~Φ100mm

type C

Φ80mm~Φ130mm

Protection class

Indicator

IP40

Sensor

IP65

Fiber cable length for short circuit sensor

 1.5m can be customized

Fiber cable length for grounding sensor

 2.5m can be customized

Panel window size (WxH)

92x45mm

Indicator size (WxHxD)

96X48x69mm

Sensor size (WxHxD)

40x44x27mm



Hot Products
  • Short Circuit and Earth Fault Detector working principle

    Short Circuit and Earth Fault Detector

    EKL4B Short Circuit and Earth Fault Detector indicates high voltage power line short circuit fault by detecting the 3 single-phase line-currents and short circuit currents, and the grounding fault by detecting the zero sequence currents. With visual or audible indicators, it helps line patrol staff to fast find out the location where there is a short circuit or grounding fault on the 3kV-40.5kV power distribution networks, switchgears or cable branching units etc.

  • VPIS High Voltage Indicator

    High Voltage Indicator

    DXN3-T High Voltage Indicator indicates the voltage status of the main circuit of the high voltage electrical equipments, preventing electrical misoperation and accidental entry into the area with high voltage presence.

  • RMU instrument transformer

    Instrument Transformer

    LMZK3 split core instrument transformer is suitable for measurement of primary current, or for protection of electrical equipments such as microcomputer in 10KV and 35KV AC power distribution networks. It is widely used in fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes. The transformer can be directly installed at the inlet and outlet of the GIS or AIS cables. The semicircular ring core and secondary windings are vacuum poured by insulated resin. This CT is also used for signal acquisition for RTU or FTU.

  • Motor Drive Operating Mechanism working principle

    Motor Drive Operating Mechanism

    AD DC 3 – S / AC220 series of Motor Drive Operating Mechanism are applicable for modules of ABB safe cabinets. Operated by motor gear, it can store energy to make-and-break the circuit breakers of MV switchgears. Functions include Remote/local switching and local make-and-break of switches, local and remote indication of the status of load switches, earth switches and fuses.

  • Switchgear temperature control

    Switchgear Temperature Controller

    KST series of small-sized temperature controller and bimetallic thermostat dedicated for switchgears 10℃. It can automatically start fans or heaters and adjust temperature and humidity of the surrounding according to on-site situation. The contacts will output action indication signals, when ambient temperature is higher than pre- set temperature, the contact of controller will flip so to protect the equipments from being damaged.

Send a message

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Contact Us
Xiamen Andaxing Electric Group Co.,Ltd TEL:86-592-3102888 or 3170079 FAX:86-592-3170008 Email : ade@cnade.net ADD:58th, Siming Park, Tong’an Industrial Zone, Xiamen, China. Zip Code : 361100 Websites : www.andaxingelectric.com  www.andaxing.net   www.cnade.net
related products
Short Circuit Earth Fault Indicator
Short Circuit and Earth Fault Indicator
EKL1 Short Circuit and Earth Fault Indicator indicates high voltage power line short circuit fault by detecting the 3 single-phase line-currents and short circuit currents, and the grounding fault by detecting the zero sequence currents. With visual or audible indicators, it helps line patrol staff to fast find out the location where there is a short circuit or grounding fault on the 3kV-40.5kV power distribution networks, switchgears or cable branching units etc.
Earth Fault Short Circuit Indicator
Earth Fault and Short Circuit Indicator
EKL1B Earth Fault and Short Circuit Indicator indicates high voltage power line short circuit fault by detecting the 3 single-phase line-currents and short circuit currents, and the grounding fault by detecting the zero sequence currents. With visual or audible indicators, it helps line patrol staff to fast find out the location where there is a short circuit or grounding fault on the 3kV-40.5kV power distribution networks, switchgears or cable branching units etc.
Short circuit ground fault indicator
Short Circuit and Ground Fault Indicator
EKL5 Short Circuit and Ground Fault Indicator indicates high voltage power line short circuit fault by detecting the 3 single-phase line-currents and short circuit currents, and the grounding fault by detecting the zero sequence currents. With visual or audible indicators, it helps line patrol staff to fast find out the location where there is a short circuit or grounding fault on the 3kV-40.5kV power distribution networks, switchgears or cable branching units etc.
Short circuit and earth fault indicator
Short Circuit Earth Fault Indicator
EKL2 Short Circuit Earth Fault Indicator indicates high voltage power line short circuit fault by detecting the 3 single-phase line-currents and short circuit currents, and the grounding fault by detecting the zero sequence currents. With visual or audible indicators, it helps line patrol staff to fast find out the location where there is a short circuit or grounding fault on the 3kV-40.5kV power distribution networks, switchgears or cable branching units etc.
Short Circuit and Earth Fault Indicating Device
Short Circuit Earth Fault Indicating Device
EKL4 Short Circuit Earth Fault Indicating Device indicates high voltage power line short circuit fault by detecting the 3 single-phase line-currents and short circuit currents, and the grounding fault by detecting the zero sequence currents. With visual or audible indicators, it helps line patrol staff to fast find out the location where there is a short circuit or grounding fault on the 3kV-40.5kV power distribution networks, switchgears or cable branching units etc.
three phase fault indicator
Fault Indicator
EKL3 Short Circuit and Earth Fault Indicator indicates high voltage power line short circuit fault by detecting the 3 single-phase line-currents and short circuit currents, and the grounding fault by detecting the zero sequence currents. With visual or audible indicators, it helps line patrol staff to fast find out the location where there is a short circuit or grounding fault on the 3kV-40.5kV power distribution networks, switchgears or cable branching units etc
Short circuit ground fault passage indicator
Fault Passage Indicator
EKL7 Short Circuit and Ground Fault Passage Indicator indicates high voltage power line short circuit fault by detecting the 3 single-phase line-currents and short circuit currents, and the grounding fault by detecting the zero sequence currents. With visual or audible indicators, it helps line patrol staff to fast find out the location where there is a short circuit or grounding fault on the 3kV-40.5kV power distribution networks, switchgears or cable branching units etc.
LMZK6 Split Core Current Transformer andaxing
LMZK6 Split Core Current Transformer
LMZK series split core current transformer is suitable for measurement of primary current , or for protection of electrical equipments such as microcomputer in 10KV and 35KV AC power distribution networks. It is widely used in fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes. The transformer can be directly installed at the inlet and outlet of the GIS or AIS cables. The semicircular ring core and secondary windings are vacuum poured by insulated resin. This CT is also used for signal acquisition for RTU or FTU.

copyright © 2018 Xiamen Andaxing Electric Group Co.,Ltd all rights reserved. powered by dyyseo.com

welcome to Andaxing
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!
   

online service

home

products

about

contact